MRN
Lower Flowmeter Module
Description:
The module is designed for measuring the flow rates of well fluid in the casing string of injection and production wells.
The module operates only in conjunction with KSA-T12, KSA-T11, KSA-T8, or KSA-T5 modules and serves as a terminal module.
Applications:
- Flow rate measurement
- Identification of producing intervals in a production well
- Determination of fluid absorption profile in the formation (formation layers) of an injection well
- Detection of casing leaks
- Identification of fluid inflow intervals in the well
Technical Specifications:
|
Number |
Name |
Conventional designation |
Range |
Error |
Permission |
|
01 |
Flow rate, m³/h |
Q |
1…60 |
±5% |
0,01 |
Design options:
|
|
MRN.38-120/60 |
MRN.43-120/60 |
MRN.38-150/80 |
MRN.43-150/80 |
MRN.43-180/100 |
MRN.43-180/120 |
|
Maximum operating temperature, °С |
120 |
120 |
150 |
150 |
180 |
180 |
|
Maximum working pressure, MPa |
60 |
60 |
80 |
80 |
100 |
120 |
|
Diameter, mm |
38 |
43 |
38 |
43 |
43 |
43 |
|
Length, mm |
555 |
555 |
555 |
555 |
555 |
555 |
|
Weight, no more |
3 |
3 |
3 |
3 |
3 |
3 |
ООО ГРУППА КОМПАНИЙ «КомпАС»
620100 г. Екатеринбург, ул. Восточная, строение 160А, помещение 17/41
+7 (343) 345-13-63
gcc@gccompas.ru